Got a Question? Give the team a call now on +44 1422 310800
£415.00
HPC LASER (LASERSCRIPT) CW4000 chiller unit suitable for water cooled co2 laser tubes. Ideal for heavier production or in warm environment, will protect your tube and keep your beam accurate!
The cw4000 unit contains refrigerator gases and actively cools the recirculating water circulating
Filling
The cw4000 has a capacity of 3.2 litres and should be filled to just above the cooling coils
Temperature
Our chiller units are set up to maintain the water temperature at a constant 18 degrees. The temperature is likely to increase under intensive use and the chiller will alert the user with an alarm sound if the temperature exceeds 25 degrees and will display the error message E02.
Flow
The chiller unit has its own pump if a chiller unit is fitted the standard pump is no longer required.
The chiller unit monitors the flow rate of water and it will emit a warning sound and display the error message E05 if the flow rate is too low, this could be caused by kinks in the water tubing or blockages in the piping, if the error message is displayed checked all the water pipes for kinks or tight turns and check the water quality, if the water is murky it should be replaced.
Available from UK stock and delivered via courier usually within 2 to 3 working days of your order.
SPEC:
Power Supply: AC 220, 240V 50HZ
Current:
Water capacity: 3.2L
Refrigerant: R134a
Cooling Capacity: 2064 Btu/h
Dimensions: Length 350mm x 420 width x 500mm height
Weight: 30KG
Inlet / Outlet: Rp 1/2 (DN15)
Drain: Rp 1/2 (DN15)
Not available to purchase online – please contact us to order
Out of stock
CW4000 chiller unit suitable for water cooled CO2 laser tubes. Ideal for heavier production or in warm environment, will protect your tube and keep your beam accurate!
The CW4000 unit contains refrigerator gases and a compressor and actively cools the recirculating water. Suitable for use with laser tubes up to 150W.
Filling
The cw4000 has a capacity of 3.2 litres and should be filled to just above the cooling coils
Temperature
Our chiller units are set up to maintain the water temperature at a constant 18 degrees. The temperature is likely to increase under intensive use and the chiller will alert the user with an alarm sound if the temperature exceeds 25 degrees and will display the error message E02.
Flow
The chiller unit has its own pump if a chiller unit is fitted the standard pump is no longer required.
The chiller unit monitors the flow rate of water and it will emit a warning sound and display the error message E05 if the flow rate is too low, this could be caused by kinks in the water tubing or blockages in the piping, if the error message is displayed checked all the water pipes for kinks or tight turns and check the water quality, if the water is murky it should be replaced.
Available from UK stock and delivered via courier usually within 2 to 3 working days of your order.
SPECIFICATION:
Power Supply: AC 220, 240V 50HZ
Current:
Water capacity: 3.2L
Refrigerant: R134a
Cooling Capacity: 2064 Btu/h
Dimensions: Length 350mm x 420 width x 500mm height
Weight: 30KG
Inlet / Outlet: Rp 1/2 (DN15)
Drain: Rp 1/2 (DN15)
Not available to purchase online – please contact us to order
You must be logged in to post a review.
Reviews
There are no reviews yet.